LG100 Brake Module


The brake module LG100 serves to provide prototypical slowing and stopping of digital locomotives in front of a 'red' signal.

LG100 generates the control signals for a booster, just like the command station LZ100. The LG100 does not have an amplified output for connection to the track. For operation, a booster LV100 with its corresponding transformer is needed.

Please select from the following


Function of LG100:

LG100 Index | Lenz GmbH Home Page


Connecting LG100 to command station LZ100 and booster LV100:

Illustration 1 shows the connection of the brake module to command station LZ100 on one hand and booster LV100 on the other.

On each side of the brake module is a 3 connector screw strip. The connectors CDE (von LZ100 [from LZ100]) on the right side are to be wired to the corresponding connectors on the command station LZ100. The outputs on the left side (zum LV100 [to LV100]) are wired to the corresponding connectors on the booster LV100. Twist the wires at connectors C and D respectively.

The upper part of illustration 1 also shows the connection of a booster LV100 to the command station LZ100, just like you are already familiar with it.

The upper booster outputs a 'normal' digital signal at position A; the lower LV100 outputs the special brake module signal, as described above, at position B.

LG100 Index | Lenz GmbH Home Page


Connection suggestions

Relay 1 (twin-coil) serves to switch the block between command station signal 'A' and the brake module signal 'B'.

Relay 2 (twin-coil) ensures that when the signal shows 'green', the section is not switched to the brake module signal (This relay activates the track contact, TC). If the signal shows 'green', then the connection to the track contact is interrupted by relay 2. In other words, relay 2 is connected in parallel with the signal drive and switched with it.

LG100 Index | Lenz GmbH Home Page


The sequence of events at a 'red' signal

Important:

If the block is fed the signal from the brake module, then the double gaps in the track between the block and the section before and after must not be run over. If they are, you will have a short circuit and DIGITAL plus will switch into EMERGENCY STOP!

As a polarity free (isolated) track contact, you can use, for example, the ROCO contact track 42518, or also a REED contact. In case of the latter, you must install a magnet in the cab car of pushed trains (in the first car in the direction of travel).

Another option is to use a current sensor. Then you must have a double gap in the track between the operating and the stop sections, and monitor the stop section with the current sensor. Now you switch over to the brake module as soon as a current user enters the stop section. In pushed trains you need to equip the first car with interior lighting. If you use the Arnold universal relay 86077 as the relay, the track contact does not have to be isolated. Please see the manual of the universal relay for information on how to connect such track contacts (for example Arnold 7440).

Illustration 1: Conneting the brake module to LZ100 and LV100

lg1001.jpg (36113 bytes)

Illustration 2: Suggested connection schematic

lg1002.jpg (22308 bytes)

LG100 Index | Lenz GmbH Home Page



Copyright 1995-2003 by Lenz Elektronik, GmbH. All Rights Reserved